DO Sensor | Interface | With waterproof connector | |
| Principle | Fluorescence method | ||
| Range | 0-20mg/L or 0-200% SAT | ||
| Accuracy | ±5% or ±0.3 NTU (Take the larger value) | ||
| Resolution | 0.01mg/L | ||
| Material | Ti | ||
| Output | RS485, MODBUS | ||
|
Conductivity (Salinity) Sensor | Interface | With waterproof connector | |
| Principle | Four electrode method | ||
| CT Range | 0.01~5mS/cm or 0.01~100mS/cm | ||
| CT Accuracy | <1% or 0.01mS/cm (Take the larger value) | ||
| SAL Range | 0~2.5ppt or 0~80ppt | ||
| SAL Accuracy | ±0.05ppt or ±1ppt | ||
| Material | Ti+PEEK+Nickel | ||
| Output | RS485, MODBUS | ||
|
Turbidity Sensor | Interface | With waterproof connector | |
| Principle | 90° scattered light | ||
| Range | 0 – 1000 NTU | ||
| Accuracy | ±5% or 0.3 NTU | ||
| Resolution | 0.01 NTU | ||
| Material | Ti | ||
| Output | RS485, MODBUS | ||
|
pH Sensor | Interface | With waterproof connector | |
| Principle | Electrode method | ||
| Range | 0-14pH | ||
| Accuracy | ±0.02pH | ||
| Resolution | 0.01 | ||
| Material | POM + Ti | ||
| Output | RS485, MODBUS | ||
|
Chlorophyll Sensor | Interface | With waterproof connector | |
| Principle | Fluorescence method | ||
| Range | 0~400 µg/L or 0~100RF | ||
| Accuracy | ±5% or 0.5?g/L (Take the larger value) | ||
| Resolution | 0.01 ?g/L | ||
| Material | Ti | ||
| Output | RS485, MODBUS | ||
| BGA Sensor | Interface | With waterproof connector | |
| Principle | Fluorescence method | ||
| Range | 0-200,000 cells/mL | ||
| Detection limit | 300 cells/mL | ||
| Linearity | R²>0.999 | ||
| Resolution | 1 cells/mL | ||
| Material | Ti | ||
| Output | RS485, MODBUS | ||
|
ORP Sensor | Interface | With waterproof connector | |
| Principle | Electrode method | ||
| Range | -999~999mV | ||
| Accuracy | ±20mV | ||
| Resolution | 1mV | ||
| Material | POM + Ti | ||
| Output | RS485, MODBUS | ||
|
OIW Sensor | Interface | With waterproof connector | |
| Principle | Fluorescence method | ||
| Range | 0-50 ppm | ||
| Accuracy | 0.01ppm | ||
| Resolution | R²>0.999 | ||
| Material | Ti | ||
| Output | RS485, MODBUS | ||
|
Other Information | Sensor body | 7 waterproof ports, support up to 6 digital sensor access, 1 central cleaning brush, probe and cleaning brush can be disassembled, free combination. | |
| Size | ?81mm *476mm | ||
| Temperature | 0~50°C | ||
| Calibration data | Calibration data is stored in the probe, which can be disassembled and taken to the laboratory for calibration. | ||
| Output | RS485, MODBUS | ||
| Automatic cleaning | Yes | ||
| Brush control | The default cleaning interval is 30 minutes But you can set the cleaning interval | ||
| Power supply | Sensor: DC 12~24V, ?1A; Single probe: 9~24V, ?1A | ||
| Protection level | IP68 | ||
| Material | POM, copper sheet | ||
| State alarm | There are voltage abnormal alarms, water leakage alarms, and self-cleaning brush abnormal alarms | ||
| Cable length | With waterproof connector, 10m (default), customizable | ||
| Protection cover | Multiparameter Sonde protection cover is standard |